6685-00-906-3959

Description: Di Compound Pressure-vacuum Gage

Price Quote

Qty:
Email Address:
Phone Number:
Company:
Privacy    Terms

Quality Assurance

We are commited to quality and satisfaction as a certified supplier in the aerospace and military industries.

  • Certificate of Conformity
  • QC Inspection prior to shipping
  • On time delivery
  • International Shipping Available
  • Friendly service to back every order
MILSPEC: MIL-G-18997

 Export Restrictions

Any part(s) quoted or sold by MilSpec.parts and re-sold (to a third party) CANNOT be sold to a USA embargoed country, company, entity, or person(s). Depending on the ECCN, these commodities may require export license or exception. Diversion contrary to U.S. law is prohibited. Unless otherwise noted, this sale, order or quote may include Munitions List Items (MLI) or Commerce Controlled List Items (CCLI). MLI/CCLI property is controlled by the US Government and in many cases cannot be transferred (exported, sold or given) to a foreign country, a non-US Citizen/National or a non- Permanent US Resident without a valid State/Commerce Department export authorization. It is the responsibility of (the Purchaser) to determine what the applicable requirements may be, to obtain all necessary authorizations, licenses or approvals and are subject to both review and acceptance by MilSpec.parts. The use, disposition, export and re-export of the property covered or included in this sale, order or quote is subject to the provisions of law referenced in End-Use Certificate DLA form 1822, DEC 2001, including, but not limited to, the Arms Export Control Act (22 USC 2751 et seq.); Export Administration Act of 1979 (50 USC App. 2401 et seq.) as contained under Executive Order 12924; International Traffic in Arms Regulations (22 CFR 120 et seq.); Export Administration Regulations (15 CFR 730 et seq.); Foreign Assets Control Regulations (31 CFR 500 et seq.) and the Espionage Act (18 USC 793 et seq.)

More MIL-G-18997 Parts

MIL-G-18997 Di Compound Pressure-vacuum Gage

Spec. Type Spec. Color Gloss Size
Actuating element material MIL-G-18997

Array Properties

  • NSN:
    Array
  • Description:
    Di Compound Pressure-vacuum Gage
  • Shelf Life:
    N/A
  • DEMIL:
    NO
  • UOM:
    1 EA
  • Overall Depth:
    2.406 inches
  • Overall Diameter:
    4.969 inches
  • Case Material:
    Aluminum
  • Case Surface Treatment:
    Any acceptable
  • End Application:
    Poseidon material
  • Graduation Unit:
    10.0 inches and 50.0 pounds per square inch
  • Actuation Type:
    Bourdon tube
  • Adjustability:
    Adjustable
  • Scale Range:
    +0.0/+36.0 inches of mercury and +0.0/+300.0 pounds pressure per square inch
  • Scale Name:
    Pressure-vacuum
  • Dial Size:
    4-1/2 in. Dia
  • Connection Quantity:
    1
  • Pointer Color:
    Black and red
  • Pointer Type:
    Indicating and reference
  • Scale Type:
    Dial
  • Scale Smallest Increment:
    1.0 inches and 5.0 pounds per square inch
  • Connection Type:
    External
  • Mounting Method:
    Surface
  • Scale Accuracy:
    Porm 1 pct full scale
  • Actuating Element Material:
    Nickel copper aluminum alloy or nickel-chromium-iron alloy
  • Scale Inscription/background Color:
    Black markings on white background
  • Scale Name For Which Pointer Is Designed:
    Pressure-vacuum
  • Connection Location:
    Back
  • Protective Crystal Material:
    Plastic
  • Connection Size:
    0.250 in. Tube
  • Connector Type Vent:
    Not provided
  • Special Features:
    Pac apsk should read 0/30 in. And 0/300 psi
  • Nondefinitive Specification/std Data:
    A design and c type
Manufacturers and Part Numbers
Part Number
Brand
SC4ND3HCWRANAG
Military Specifications
MIL-G-18997
Military Specifications
45-1246PC33BXWDFF076
Ashcroft .
SA24-3CTP-RWBX
Weksler Glass Thermometer Corp
Major Organizational Entities (MOE)
Entity
MOE Code
MOE Rule
PICA
DSOR
User:
DEPARTMENT OF THE NAVY Dept. of the Navy
MOE_CD:
DN
MOE_RL:
N9BG
PICA:
GX
DSOR:
Part Identification
INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
07424
FIIG:
T179-B
Concept No.:
App. Key:
BA
Cond. Code:
1
Status:
A
Material and Special Handling
Hazardous material, precious metals, criticality, enviroment, and electrostatic discharge indicators
HMIC
PMIC
ESD/EMI
ENAC
MMAC
CRITL
HMIC:
P
PMIC:
U
ESD:
ESD:
MMAC:
---
CRITL:
X
Hazmat (HMIC): P
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Precious Metals (PMIC): U
Precious metal content is unknown
Criticality (CRITL): X
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Packaging and Dimensions
Package Size
Package Weight
Part Weight
Part Dimensions (approx.)
Pack Size:
--
Pack Weight:
2.8000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
Container:
E9
OPI:
M
SPI No.:
SPI Rev.:
SPC Mkg.
LVL A
LVL B
LVL C
SPC Mkg.:
05
LVL A:
E
LVL B:
Q
LVL C:
CUSH
MOP
CATEG.
PRESS MAT
CUSH:
NA
MOP:
ZZ
CATEG.:
13Z0
PRESS MAT:
00
WRAP MAT
ICQ
THK
TOS
UCL
WRAP MAT:
ZZ
ICQ:
XXX
THK:
X
TOS:
UCL:
Packaging Code Definitions
LVL A Code (LVL_A):E
Packing shall be accomplished to meet the performance test requirements of astm-d4169, distribution cycle 18, assurance level 1.
LVL B Code (LVL_B): Q
Packing shall be accomplished in accordance with table c.Ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with the appropriate shipping container specification.
Procedure Indicator Code (OPI): M
All packaging data is mandatory for compliance and no substitutions are permitted. fast packs should be included in this category.
Special Markings Code (SPC MKG): 05
Delicate instrument.
Method of Preservation (MOP): ZZ
See j.4.1.B.
Cushion Material (CUSH): NA
Ppp-c-795, cellular plastic film cushioning; or a-a-3129, open cell plastic cushioning; or ppp-c-1797, polypropylene foam cushioning; or a-a-59136, polyethylene foam cushioning.
Preservation Material (PRESS MAT): 00
No requirement.