6665-01-112-6532
Description: Radiacmeter
Price Quote
Quality Assurance
We are commited to quality and satisfaction as a certified supplier in the aerospace and military industries.
- Certificate of Conformity
- QC Inspection prior to shipping
- On time delivery
- International Shipping Available
- Friendly service to back every order
Export Restrictions
Any part(s) quoted or sold by MilSpec.parts and re-sold (to a third party) CANNOT be sold to a USA embargoed country, company, entity, or person(s). Depending on the ECCN, these commodities may require export license or exception. Diversion contrary to U.S. law is prohibited. Unless otherwise noted, this sale, order or quote may include Munitions List Items (MLI) or Commerce Controlled List Items (CCLI). MLI/CCLI property is controlled by the US Government and in many cases cannot be transferred (exported, sold or given) to a foreign country, a non-US Citizen/National or a non- Permanent US Resident without a valid State/Commerce Department export authorization. It is the responsibility of (the Purchaser) to determine what the applicable requirements may be, to obtain all necessary authorizations, licenses or approvals and are subject to both review and acceptance by MilSpec.parts. The use, disposition, export and re-export of the property covered or included in this sale, order or quote is subject to the provisions of law referenced in End-Use Certificate DLA form 1822, DEC 2001, including, but not limited to, the Arms Export Control Act (22 USC 2751 et seq.); Export Administration Act of 1979 (50 USC App. 2401 et seq.) as contained under Executive Order 12924; International Traffic in Arms Regulations (22 CFR 120 et seq.); Export Administration Regulations (15 CFR 730 et seq.); Foreign Assets Control Regulations (31 CFR 500 et seq.) and the Espionage Act (18 USC 793 et seq.)
6665-01-112-6532 Properties
-
NSN:6665-01-112-6532
-
Description:Radiacmeter
-
Shelf Life:N/A
-
DEMIL:DEMIL/MLI
-
UOM:1 EA
-
Overall Length:4.500 inches
-
Overall Diameter:0.562 inches
-
Mounting Method:Clip
-
Case Material:Aluminum or plastic
-
Carrying Case:Not provided
-
Usage Design:Low energy doisimeter; one applications is in flouroscopy and angiography proceedures
-
Internal Battery Accommodation:Not included
-
Indicator Type:Optical quartz fiber electrometer
-
Radiation Type And Function:X-rays measures
-
Detecting Element Type:Ionization chamber
-
Portability:Portable
-
Radiation Range Per Hour:+0.0/+500.0 milliroentgens
-
Energy Dependence Rating:+18.0/+250.0 kev
-
Err Default:Err default
-
Special Features:Accuracy 15% of true dose at 30 kev; scale division 25 milliroentgens; charging voltage 200 vdc
-
Reference Data And Literature:Commercial catalog