6525-01-130-4930

Description: Radiographic And X-ray Apparatus

Price Quote

Qty:
Email Address:
Phone Number:
Company:
Privacy    Terms

Quality Assurance

We are commited to quality and satisfaction as a certified supplier in the aerospace and military industries.

  • Certificate of Conformity
  • QC Inspection prior to shipping
  • On time delivery
  • International Shipping Available
  • Friendly service to back every order
MILSPEC: Veterinary Dental Imaging Equipment And Supplies: Medical

 Export Restrictions

Any part(s) quoted or sold by MilSpec.parts and re-sold (to a third party) CANNOT be sold to a USA embargoed country, company, entity, or person(s). Depending on the ECCN, these commodities may require export license or exception. Diversion contrary to U.S. law is prohibited. Unless otherwise noted, this sale, order or quote may include Munitions List Items (MLI) or Commerce Controlled List Items (CCLI). MLI/CCLI property is controlled by the US Government and in many cases cannot be transferred (exported, sold or given) to a foreign country, a non-US Citizen/National or a non- Permanent US Resident without a valid State/Commerce Department export authorization. It is the responsibility of (the Purchaser) to determine what the applicable requirements may be, to obtain all necessary authorizations, licenses or approvals and are subject to both review and acceptance by MilSpec.parts. The use, disposition, export and re-export of the property covered or included in this sale, order or quote is subject to the provisions of law referenced in End-Use Certificate DLA form 1822, DEC 2001, including, but not limited to, the Arms Export Control Act (22 USC 2751 et seq.); Export Administration Act of 1979 (50 USC App. 2401 et seq.) as contained under Executive Order 12924; International Traffic in Arms Regulations (22 CFR 120 et seq.); Export Administration Regulations (15 CFR 730 et seq.); Foreign Assets Control Regulations (31 CFR 500 et seq.) and the Espionage Act (18 USC 793 et seq.)

6525-01-130-4930 Properties

  • NSN:
    6525-01-130-4930
  • Description:
    Radiographic And X-ray Apparatus
  • Shelf Life:
    N/A
  • DEMIL:
    NO
  • UOM:
    1 EA
  • Drive Type:
    Motor
  • Accessory Components And Quantity:
    Adjustable non-skid footrest 1; compression-immobilization device 1; head clamp 1; patient grasp handles 1 pr; skidproof patient step 1; should rest 1; urological knee crutches 1 pr
  • Design Type:
    Stationary
  • Tube Quantity:
    2
  • Tube Type:
    Double focus, rotating anode fluoroscopic and double focus, rotating anode radiographic
  • Table Type:
    Tilting
  • Rectification Type:
    Full-wave
  • Tube Cooling Method:
    Air
  • Tube Mounting Type:
    Table and tube stand
  • Tube Stand Mounting Type:
    Floor
  • Err Default:
    Err default
  • Err Default:
    Err default
  • Transformer Rectification Method:
    Self-rectifying
  • Transformer Output Capacity:
    To 300 ma at 150 kv peak
  • Part Name Assigned By Controlling Agency:
    X-ray apparatus: high capacity radiographic and fluroscopic
  • Voltage In Volts:
    190.0 and 270.0
  • Phase:
    Single
  • Special Features:
    40000 watt; automatic collimator; bucky diaphram; spot film device; 24 by 24 cm front-end loading device; solid state
  • Frequency In Hertz:
    50.0 or 60.0
  • Supplementary Features:
    Use w/image intensifier; overhead tube mount; vertical cassette holder; for use in field assembly only
Manufacturers and Part Numbers
Part Number
Brand
1-1044F
Onyx Medical Corporation
Major Organizational Entities (MOE)
Entity
MOE Code
MOE Rule
PICA
DSOR
User:
DEPARTMENT OF THE ARMY Dept. of the Army
MOE_CD:
DA
MOE_RL:
A911
PICA:
GX
DSOR:
User:
U.S. MARINE CORPS U.s. Marine Corps
MOE_CD:
DM
MOE_RL:
MC55
PICA:
GX
DSOR:
User:
DEPARTMENT OF THE NAVY Dept. of the Navy
MOE_CD:
DN
MOE_RL:
N9BL
PICA:
GX
DSOR:
Part Identification
INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
06321
FIIG:
T140-C
Concept No.:
App. Key:
CA
Cond. Code:
2
Status:
A
Material and Special Handling
Hazardous material, precious metals, criticality, enviroment, and electrostatic discharge indicators
HMIC
PMIC
ESD/EMI
ENAC
MMAC
CRITL
HMIC:
P
PMIC:
A
ESD:
ESD:
MMAC:
---
CRITL:
X
Hazmat (HMIC): P
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Precious Metals (PMIC): A
Item does not contain precious metal.
Criticality (CRITL): X
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Packaging and Dimensions
Package Size
Package Weight
Part Weight
Part Dimensions (approx.)
Pack Size:
--
Pack Weight:
--
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
Container:
OPI:
SPI No.:
SPI Rev.:
SPC Mkg.
LVL A
LVL B
LVL C
SPC Mkg.:
LVL A:
LVL B:
LVL C:
CUSH
MOP
CATEG.
PRESS MAT
CUSH:
MOP:
CATEG.:
PRESS MAT:
WRAP MAT
ICQ
THK
TOS
UCL
WRAP MAT:
ICQ:
THK:
TOS:
UCL:
Packaging Code Definitions
LVL A Code (LVL_A):
LVL B Code (LVL_B):
Procedure Indicator Code (OPI):
Special Markings Code (SPC MKG):
Method of Preservation (MOP):
Cushion Material (CUSH):
Preservation Material (PRESS MAT):