MIL-PRF-39012 Parts

Page 1 of 3
 

Our Quality Assurance

We are committed to quality and satisfaction as a certified supplier in the aerospace and military industries.

  • Certificate of Conformity

  • QC Inspected before shipping

  • Fast On-Time Delivery

  • International Shipping Available

  • Friendly service

Purchasing Information

  • GOVERNMENT CREDIT CARDS

  • PRICING AND PAYMENT

    If payment is being made by credit card, MilSpec.parts is authorized to charge the credit card presented for the specified items, and any additional shipping charges to the final destination.

  • MATERIAL CONDITIONS

    • FN - Factory New
    • NE - New Material
    • NS - New Unused Surplus
    • OH - Overhauled
    • SV - Serviceable
    • RP - Repairable
    • AR - As Removed/Used

    All material will be accompanied by a MilSpec.parts Certificate of Conformance, and any other documents/trace when applicable.

  • DELIVERY

    Any order placed after 2:00 PM EST (In Stock Items), may not ship until the next business day. Delivery dates for NON-STOCK items are estimates based on current backlog and are subject to confirmation at the time of order.

  • ORDER CANCELLATION

  • LIMITATION OF LIABILITY

  • !IMPORTANT EXPORT INFORMATION!

5985-01-613-1725 Fixed Attenuator

Sma female conn. Per mil-prf-39012 on both ends of attenuator

5935-01-588-0328 Coaxial Test Adapters

Constructed from gold-plated beryullium copper and stainless steel; 50 ohm; dc to 18 ghz; 0.15 db insertion loss and 1.40: 1 vswr at 18 ghz; conforms to mil-prf-39012; type: n-plug-tnc jack

5996-01-557-1114 Radio Frequency Amplifier

Amplifiers shall be supplied with two sma female connectors, mil-prf-39012

5935-01-552-4360 Electrical Plug Connector

81349-mil-prf-39012 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "nominal", etc.).

5995-01-550-6185 Radio Frequency Cable Assembly

Next assembly:196805-01; drawing number:196763; this procurement control drawing describes the requirements for ultra low loss rf coaxial cable assembly terminated with tnc connectors; the cable will be used in a marine environment; the cable length shall be 97.83 to 98.83 feet of continuous coaxial cable; the maximum vswr will be 1.40:1, 50 ohm impedance; the insertion shall be less than 8.5 db, maximum at 2.0 ghz; required connector per mil-prf 39012, p1:ptnc male, straight, passivated stainless steel, p2:ptnc male, straight, pasivated stainless steel; the cable shall with stand a pull test of 80 lbs. Minimum per mil-prf-39012

5995-01-550-6184 Radio Frequency Cable Assembly

Connector pull test:80 lbs. Minimum per mil-prf-39012; next assembly:196805-01; cable label:w2; drawing number:196781; length shall be 74.83 to 75.83 feet of continuous coaxial cable; the maximum vswr will be 1.40:1, 50 ohm impedance; attenuation:the insertion loss shall be less than 17.0 db, maximum at 18.0 ghz; this procurement control drawing describes the requirement for ultra low loss rf coaxial cable assembly terminated with tnc connectors; the cable will be used in a marine environment

5995-01-550-6182 Radio Frequency Cable Assembly

Connector pull test:80 lbs. Minimum per mil-prf-39012; next assembly:196805-01; cable label:w9; drawing number:196781; length shall be 74.83 to 75.83 feet of continuous coaxial cable; the maximum vswr will be 1.40:1, 50 ohm impedance; attenuation:the insertion loss shall be less than 17.0 db, maximum at 18.0 ghz; this procurement control drawing describes the requirement for ultra low loss rf coaxial cable assembly terminated with tnc connectors; the cable will be used in a marine environment

5995-01-550-6181 Radio Frequency Cable Assembly

Connector pull test:80 lbs. Minimum per mil-prf-39012; next assembly:196805-01; cable label:w8; drawing number:196781; length shall be 74.83 to 75.83 feet of continuous coaxial cable; the maximum vswr will be 1.40:1, 50 ohm impedance; attenuation:the insertion loss shall be less than 17.0 db, maximum at 18.0 ghz; this procurement control drawing describes the requirement for ultra low loss rf coaxial cable assembly terminated with tnc connectors; the cable will be used in a marine environment

5995-01-550-6180 Radio Frequency Cable Assembly

Connector pull test:80 lbs. Minimum per mil-prf-39012; next assembly:196805-01; cable label:w6; drawing number:196781; length shall be 74.83 to 75.83 feet of continuous coaxial cable; the maximum vswr will be 1.40:1, 50 ohm impedance; attenuation:the insertion loss shall be less than 17.0 db, maximum at 18.0 ghz; this procurement control drawing describes the requirement for ultra low loss rf coaxial cable assembly terminated with tnc connectors; the cable will be used in a marine environment

5995-01-550-6179 Radio Frequency Cable Assembly

Connector pull test:80 lbs. Minimum per mil-prf-39012; next assembly:196805-01; cable label:w7; drawing number:196781; length shall be 74.83 to 75.83 feet of continuous coaxial cable; the maximum vswr will be 1.40:1, 50 ohm impedance; attenuation:the insertion loss shall be less than 17.0 db, maximum at 18.0 ghz; this procurement control drawing describes the requirement for ultra low loss rf coaxial cable assembly terminated with tnc connectors; the cable will be used in a marine environment

5995-01-550-6178 Radio Frequency Cable Assembly

Connector pull test:80 lbs. Minimum per mil-prf-39012; next assembly:196805-01; cable label:w5; drawing number:196781; length shall be 74.83 to 75.83 feet of continuous coaxial cable; the maximum vswr will be 1.40:1, 50 ohm impedance; attenuation:the insertion loss shall be less than 17.0 db, maximum at 18.0 ghz; this procurement control drawing describes the requirement for ultra low loss rf coaxial cable assembly terminated with tnc connectors; the cable will be used in a marine environment

5995-01-550-6177 Radio Frequency Cable Assembly

Connector pull test:80 lbs. Minimum per mil-prf-39012; next assembly:196805-01; cable label:w4; drawing number:196781; length shall be 74.83 to 75.83 feet of continuous coaxial cable; the maximum vswr will be 1.40:1, 50 ohm impedance; attenuation:the insertion loss shall be less than 17.0 db, maximum at 18.0 ghz; this procurement control drawing describes the requirement for ultra low loss rf coaxial cable assembly terminated with tnc connectors; the cable will be used in a marine environment

5995-01-550-6176 Radio Frequency Cable Assembly

Connector pull test:80 lbs. Minimum per mil-prf-39012; next assembly:196805-01; cable label:w3; drawing number:196781; length shall be 74.83 to 75.83 feet of continuous coaxial cable; the maximum vswr will be 1.40:1, 50 ohm impedance; attenuation:the insertion loss shall be less than 17.0 db, maximum at 18.0 ghz; this procurement control drawing describes the requirement for ultra low loss rf coaxial cable assembly terminated with tnc connectors; the cable will be used in a marine environment

5995-01-550-6175 Radio Frequency Cable Assembly

Connector pull test:80 lbs. Minimum per mil-prf-39012; next assembly:196805-01; cable label:w1; drawing number:196781; length shall be 74.83 to 75.83 feet of continuous coaxial cable; the maximum vswr will be 1.40:1, 50 ohm impedance; attenuation:the insertion loss shall be less than 17.0 db, maximum at 18.0 ghz; this procurement control drawing describes the requirement for ultra low loss rf coaxial cable assembly terminated with tnc connectors; the cable will be used in a marine environment

Disclaimers

Information/dataset on this Website may be protected by copyright laws, and may not be reproduced, republished, distributed, transmitted, displayed, broadcast or otherwise exploited in any manner without the express prior written permission of the DLA, MilSpec.parts, or the original information owner. You may download material (one copy per page) from this Website for your personal and non-commercial use only, without altering or removing any trademark, copyright or other notice from such material. MilSpec.parts name and logos, and all related trademarks (including DLA Part Numbers or NSN’s), tradenames, and other intellectual property are the property of DLA, or the original information owner, and cannot be used without its express prior written permission.